Installing a CONEKT rail lifeline on a concrete wall is done using:the R25 short rail fixing or the R25XL wide rail fixing to attach the rail directly to the concrete wallthe rigid concrete posts P300...
Installation of a CONEKT rail lifeline on a concrete wall is done via:- the short rail fixing R25 or the wide rail fixing R25XL to attach the rail directly to the concrete wall- rigid concrete posts P...
Installing a CONEKT rail lifeline on a steel structure is done using:the CRA double clamp and the SC clamping bracketthe R25 short rail fixing to attach the rail directly to the clamping bracket, or t...
The installation of a CONEKT cable lifeline on a sandwich panel is done using the PB2 plate, on which a riser must be added (AD diabolo or PB250 tilting post).Technical specifications to be observed:T...
The installation of a CONEKT manual cable lifeline on a dry deck is carried out using the PB2 plate, on which a riser must be added (AD diabolo or PB250 tilting post).Technical specifications to be ob...
The installation of a CONEKT cable lifeline on zinc decking is carried out using the ICZ plate, specially designed for this type of support. A riser (AD diabolo or PB250 tilting post) can be added if...
The installation of a CONEKT cable lifeline on a standing seam roof is carried out using the ICJD S or ICJD L plates, specially designed for this type of support. The correct plate should be selected...
The installation of a CONEKT cable lifeline on an OSB panel is carried out using the PB4 plate, on which a PB250 tilting post must be added.Technical specifications to be observed:Thickness ≥ 18...
The installation of a CONEKT cable lifeline on a waterproof roof is carried out using the PB4 plate, on which a PB250 tilting post must be added.Technical specifications to be observed:Thickness Ͱ...
The installation of a CONEKT cable lifeline on a concrete slab is carried out using the rigid concrete posts P300 or P500, depending on the desired height of 300 mm or 500 mm.Technical specifications...
The installation of a CONEKT cable lifeline on a concrete wall is carried out using the S12 or S13 wall end plates, selected according to the type of support.Technical specifications to be observed:Sp...
The installation of a CONEKT cable lifeline on a dry deck is carried out using the PB2 plate, on which a riser must be added (AD diabolo or PB250 tilting post).Technical specifications to be observed:...
The installation of a CONEKT cable lifeline on a standing seam roof is carried out using the ICJD S or ICJD L plates, specially designed for this type of support. The appropriate plate should be selec...
The installation of a CONEKT cable lifeline on an OSB panel is carried out using the PB4 plate, on which a PB250 tilting post must be added.Technical specifications to be observed:Thickness ≥ 18...
The installation of a CONEKT cable lifeline on a waterproof roof is carried out using the PB4 plate, on which a PB250 tilting post must be added.Technical specifications to be observed:Thickness Ͱ...